PIV MEASUREMENTS OF DUAL SYNTHETIC JETS ACTUATOR DRIVEN BY ELECTRICAL FACTORS

    https://doi.org/10.1142/S0217984909018540Cited by:2 (Source: Crossref)

    A dual synthetic jets actuator driven by different electrical factors was investigated using particle image velocimetry (PIV). A transfer-phase and sub-frequency technique was provided to capture the arbitrary phase of the dual synthetic jets, and a transfer-phase to equal technique was provided to determine the phase of the dual synthetic jets. The results show that both the amplitude and frequency of the electrical forcing voltages vastly affect the flow-field of the dual synthetic jets actuator. Both the forcing frequency and the driving voltage amplitudes contribute to the pressure difference and the area of the lower pressure, which determines the interactions of dual synthetic jets. The dual synthetic jet actuator exits a circumscription of electrical factors in which the actuator works efficiently.